Hunt_1995_RevisionCasingAndCementProcedures

Hunt M. 1995. To: Eubank P. Re: Hunt_1995_RevisionCasingAndCementProcedures

Please find enclosed a revised page 14 of the Plan of Operations for the subject well. The lead cement for the surface casing was changed to provide a higher compressive strength cement. This change was requested by Arnold Ott with the Railroad Commission in Corpus Christi. Since the well is in a sensitive area, the Railroad Commission felt that a higher compressive surface casing was needed. The Railroad Commission Rule 13C ii requires that the lead cement above the zone of critical cement, have a minimum compressive strength of 250 psi in 24 hrs. The lead cement that will be used in the well has a compressive strength of 1008 psi in 24 hrs. Also, the depth of the surface casing and production casing was changed to reflect a change in the directional program. Remapping of the seismic data by the geologist, required the bottom hole location to be moved further from the surface location.

Type
Administrative
Authors
Hunt, Mike
Date of Issue
1995-07-21
Units
PAIS
Keywords
casing, Cement, eubank, hunt, Letter, Ott, Plan of Operation

Full text (PDF)

Browse the catalog