Experiments with Oyster Purification in Florida

Torpey J, Ingle RM, Gillespie L, Havens WK. 1966. Experiments with Oyster Purification in Florida. Proceedings of the National Shellfisheries Association. 56:43-47

Twelve tests on purifying oysters, using ultraviolet light as the sterilizing agent, were conducted. The depuration unit employed was capable of purifying oysters using a low circulation factor at water temperatures of 24 to 26°0. No special cleaning procedure of the bivalve was necessary. In all tests except one, meats were at acceptable bacterial levels within 12 hours. In seven tests the bacterial counts of the water dropped to or remained at zero within four hours and in all tests, within 24 hours. Removal of fecal material did not appear to alter results.

Type
Journal Article
Authors
Torpey, John; Ingle, Robert; Gillespie, Larry; Havens, Walter
Units
SFCN
Keywords
Bacterial Levels, Fecal Material, Shellfish, sterilization, Ultraviolet Lights

Series

Browse the catalog