Standard Operating Procedure: Continuous Lake Temperature Monitoring
O'Donnell JA. 2018. Standard Operating Procedure: Continuous Lake Temperature Monitoring. National Park Service
This Standard Operating Procedure (SOP) describes the methods for continuous monitoring of lake temperature profiles, and is a component of the Lake Communities and Ecosystems Monitoring Protocol (O’Donnell and Miller 2018). The SOP also describes methods for site selection, lake buoy design, data logger programming, and deployment.
- Type
- Standard Operating Procedure
- Authors
- O'Donnell, Jonathan
- Date of Issue
- 2018-09
- Publisher
- National Park Service
- Keywords
- arctic, lakes, temperature