Standard Operating Procedure 1.4.24 Inventory, Maintenance, and Testing of ARD Batteries—Version 1.1
Parrish MC. 2019. Standard Operating Procedure 1.4.24 Inventory, Maintenance, and Testing of ARD Batteries—Version 1.1. Southeast Coast Network
This standard operating procedure (SOP) outlines battery inventory, maintenance, and testing practices that promote battery health and identify failing batteries. This applies to D-cell nickel-metal hydride (NiMH) rechargeable batteries used to power automatic recording devices (ARDs) deployed for audio sampling under the avian and vocal anuran vital signs monitoring protocols.
- Type
- Standard Operating Procedure
- Authors
- Parrish, Michael
- Date of Issue
- 2019-10
- Publisher
- Southeast Coast Network
- Units
- SECN
- Keywords
- amphibian, anuran, Batteries. ARD. Automated recording devices, landbird, maintenance
Other versions
- Standard Operating Procedure 1.4.24 Inventory, Maintenance, and Testing of Rechargeable ARD Batteries—Version 1.3
- Standard Operating Procedure 1.4.24 Inventory, Maintenance, and Testing of Rechargeable ARD Batteries—Version 1.2
- Standard Operating Procedure 1.4.24 Inventory, Maintenance, and Testing of ARD Batteries—Version 1.0