SFCN Water Temperature Monitoring Standard Operating Procedure WT02: Launch HOBO Temperature Pro v2 Logger—Version 1.1

South Florida/Caribbean Network. 2020. SFCN Water Temperature Monitoring Standard Operating Procedure WT02: Launch HOBO Temperature Pro v2 Logger—Version 1.1. National Park Service

This standard operating procedure (SOP) describes the steps to be taken to launch the HOBO® loggers. After a logger has passed the cold-water bath test (SOP WT01 Testing the Precision of HOBO® Loggers in a Cold Bath—Version 1.1 [SFCN 2020]), it may be stored before deployment in the field. Spare loggers that have passed the tests in SOP WT01 are often taken along in the field kit when visiting a site to be deployed if a replacement logger is needed. Such a situation may arise if a field logger is missing or if there is a problem or error in the data transfer. Prior to deployment the logger must be launched. These procedures can be performed with the loggers connected to either the base station or the waterproof shuttle. These devices can be connected to a laptop or desktop computer; therefore, this procedure can be conducted in the office or in the field.

Type
Standard Operating Procedure
Authors
South Florida/Caribbean Network
Date of Issue
2020-12
Publisher
National Park Service
Units
BISC , BUIS , DRTO , SARI , SFCN , VIIS
Keywords
Biscayne National Park, Buck Island Reef National Monument, Caribbean, Coral Reef Water Temperature, Dry Tortugas National Park, Logger, National Park Service, Reef Depth, Salt River Bay National Historical Park and Ecological Preserve, South Florida, South Florida/Caribbean Monitoring Network, Standard Operating Procedure, Temperature, U.S. Virgin Islands, Virgin Islands National Park, Water, Water Temperature
Subjects
Ecological Framework: Biological Integrity | Focal Species or Communities | Marine Communities

Full text (PDF)

See also

Browse the catalog