SOP #12: Quality Control When Changing Labs. Version 1.01. Pacific Island Network Water Quality Monitoring Protocol. Unpublished National Park Service Report, Pacific Island Inventory and Monitoring Network, Hawaii National Park, Hawaii.
Raikow D and McCutcheon A . 2024. SOP #12: Quality Control When Changing Labs. Version 1.01. Pacific Island Network Water Quality Monitoring Protocol. Unpublished National Park Service Report, Pacific Island Inventory and Monitoring Network, Hawaii National Park, Hawaii.. National Park Service
This SOP outlines quality control studies to be undertaken when a new analytical lab is contracted to analyze water quality samples for nutrients. Note that the bias test requires samples to be split and sent to both the old and new labs.
- Type
- Standard Operating Procedure
- Authors
- Raikow, David; McCutcheon, Amanda
- Date of Issue
- 2024-06-10
- Publisher
- National Park Service
- Units
- ALKA , AMME , HALE , KAHO , KALA , NPSA , PACN , PUHE , PUHO , WAPA
- Keywords
- Quality Control, Water Quality, Water Samples